Adithya - 2014-09-02 - 14163 - Rel Notes - Draft - SNC PO Extract Failed Execution #SAPReleases2014

Release Notes - Draft

14163 : SNC PO Extract Failed Execution


Admin Info


Purpose
SNC PO Extract Failed Execution
Release No
001
Submitted on
09/02/2014
Submitted by
Adithya
Environment
NECNED to NECNEQ
Sent To
Rahul Attarde
Object(s) created by
Venkat Kondapally
Object(s) tested by
Adithya
Transport Status
Created in NECNED300 / 100

Transport and Technical Objects


Sl.
Transport ID
Description
Object Name
1
NEDK927104
SNC: 14163:SNC PO Extract Failed Execution
ZSNC_PO_EXTRACT




Release Notes


For Infrastructure

N/A

For Requestor

This Release is to avoid the Dump which is seen in the month of August. We may have to monitor the job in Production Environment as we may not be able to test the same in DEV or QAS environments, due to Data issue.
Additionally this Release also takes care of the condition check "Ex Factory Date"
If a PO is given as input and if the ex Fac date of the PO is in Past no PO feed file is generated, as the ex factory date is in the past.
This check is removed with this release, Only when the Input is PO and Vendor.

Test Notes


System : NECNED300

Test ID
Test Scenario
Expected Results
Actual Results
P/F
Documents
Notes
Tested By
QA By
SNC-001
Create Few POs Z3NB and NB, Execute the PO Extract Program.
Verify the MSRP SO and MSRP PO data from the file.
A File must be generated,
MSRP values in the file must be accurate
File genarated.
If SO MSRP value is copied form ZMRP or ZCRS condition record of the SO.
If there is no SO MSRP is copied form the A552 table
p
4600007099
4600007133
4600007134
4600007136
Attached are the files:
64_PO_20140902111656.txt
65_PO_20140902111702.txt
How Ever the performance can only be checked in production Environment.
The testing is done to make sure the changes did not impact the MSRP logic.
Adithya
Adithya
SNC-002
Run the Program by giving PO as input, Ex Fac date in the PO must be in Past
A file must be generated.
File generated
P
4600006559
Attached is the file:
61_PO_20140517114434.txt
Made sure that if the PO is not given as input the Ex Fac date logic must work.
Adithya
Adithya









System: NECNEQ100


Test ID
Test Scenario
Expected Results
Actual Results
P/F
Documents
Notes
Tested By
QA By
SNC-001
Create Few POs Z3NB and NB, Execute the PO Extract Program.
Verify the MSRP SO and MSRP PO data from the file.
A File must be generated,
MSRP values in the file must be accurate
File genarated.
If SO MSRP value is copied form ZMRP or ZCRS condition record of the SO.
If there is no SO MSRP is copied form the A552 table
P
4500074650
4500074651
4500074652
4500074653
57_PO_20140909062945.txt
60_PO_20140909062947.txt
61_PO_20140909062948.txt
64_PO_20140909062949.txt
84_PO_20140909062950.txt
65_PO_20140909062950.txt
How Ever the performance can only be checked in production Environment.
The testing is done to make sure the changes did not impact the MSRP logic.
Adithya
Adithya
SNC-002
Run the Program by giving PO as input, Ex Fac date in the PO must be in Past
A file must be generated.
File generated
P

Made sure that if the PO is not given as input the Ex Fac date logic must work.











Reference Document (Specification or Production Support Break Fix)